Diesel Exhaust Fluid Article- Don’t Turn a DEF ear to low DEF.

Don’t turn DEF ear to low diesel exhaust fluid

Diesel exhaust fluid (DEF for short) is becoming more common as a key ingredient in diesel engine emission controls. Introduced to North American car drivers in certain Mercedes vehicles in 2006, it spread to the heavy trucking industry in 2007. Now DEF has hit the Detroit Three light truck market.

Ford, GM and certain Dodge diesels trucks come with an extra tank to carry the DEF necessary to meet emission regulations (the Dodge Ram 2500 and 3500 series meet the regulations without a DEF system).

DEF is essentially a 32-per-cent urea-water solution that is injected at a variable rate into the vehicle’s catalytic converter to reduce nitrous-oxide (NOx) emissions.

The amount injected is calculated by the main engine computer and varies dependent on engine load and speed as well as operating temperatures and several other in-puts. DEF is used, on average, at a rate of three per cent of the amount of fuel consumed.

When the DEF stream hits the hot inner surfaces of the catalytic converter it vaporizes and decomposes to form ammonia and carbon dioxide.

The ammonia is then used to convert the NOx emissions to harmless nitrogen and water.

For those who think the system is just another piece of technology that can be ignored, think again. If a DEF tank is left to run dry, the engine will not start.

If the tank runs low while the engine is running, a series of warning messages and lights will appear on the instrument cluster but the vehicle will continue to run until it is switched off by the driver (and then of course it will not restart).

DEF on-board tanks will hold about 30 litres of the fluid. Four-litre jugs can be purchased from most aftermarket parts stores or dealerships (that sell DEF vehicles) for around $12. In the U.S. many heavy truck refuel-ling centres dispense DEF at bulk pumps next to regular fuelling stations for as little as $4 U.S. a gallon.

REad the article at: The Ottawa Citizen

Reblogged by Lee Geurts with Krueger Sentry Gauge Company

Krueger Sentry Gauge manufactures a simple liquid level gauge for above ground bulk storage tanks that works great with DEF.

DEF Liquid Level Gauge

Above Ground Tank Installation- NFPA 30- Tank Storage

The following PDF is the NFPA Code for above ground storage tank (AST) installation.

Above-Ground-Tank-Installation-Relevant-NFPA-Code

On page 4, Section 4.3.2.3.3, letter C the code states the following:

Means shall be provided to prevent overfilling by sounding an alarm when the liquid level in the tank reaches 90 percent of capacity and by automatically stopping delivery of liquid to the tank when the liquid level in the tank reaches 95 percent of capacity. In no case shall these provisions restrict or interfere with the proper functioning of the normal vent or the emergency vent

Our Overfill alarms, when mounted to our standard liquid level gauge (Therma Gauge), provide a 110 DB alarm to warn that the tank is reaching capacity.  The following documents provide testing results and ordering info:

  • 90% Overfill Gauge Ordering
  • Intrinsically Safe Documentation on the gauge alarm
  • Recommended Maintenance and Installation Procedure on liquid level tank gauges

In cases where liquids are flammable and fire protection is paramount, adding the Glass Calibration and the Aluminum Lock Nut to the gauge should eliminate the plastic from the gauge and provide a glass and metal barrier between the inside of the tank and the outside.  For additional protection, upgrade the Aluminum Nut to the Gauge Guard.

Already have a Krueger Gauge and want to get it up to code.  If the gauge is fully functional, just order our upgraded Fire Protection Gauge Repair Kit  and an overfill alarm.  In the case of the kit, we will need to know what gauge type you have.  Example part number is (-”gauge type”-Kit-GLC-ALN). Both the kit and the alarm are easily retrofitted to existing Krueger Tank Gauges.

Prevent Oil Spills with the Krueger Overfill Alert Gauge

Oil spill from muffler shop found in creek last week – Glendale Heights, IL – Glendale Heights Press

Glendale Heights, IL —

An oil spill from a storage tank at a Midas auto shop leaked into a grated storm sewer catch basin last week at George Bell and Whitman drives in Glendale Heights.

Around 5:50 p.m. Wednesday, an oily substance was found floating in a small creek northeast of the Whitman and George Bell intersection. The Glendale Heights Public Services Department responded and began cleanup efforts. The source was traced to the Midas auto shop at 2151 Bloomingdale Road.

Oil traveled through the storm sewer system into the creek northeast of the intersection….

Prevent Overfills and Oil Spills with these Krueger Sentry Gauge Products:
The Overfill Alert Gauge and the Audible Alarm Accessory
Krueger Sentry Gauge Co. Inc.

https://www.ksentry.com

Colorado AST Tank Regulations changes as of April 2011

Committed to streamlining the operation and performance of risk

Above Ground Storage Tank Regulations. Changes to the aboveground storage tank (AST) regulations were effective April 14,. 2011. Changes were made to
www.cdphe.state.co.us/op/wqcc/…/SB181arDOPS2011.pdf
The above document states some changes regarding AST Regulations in the State of Colorado.  Important notes in regards to Krueger Sentry Liquid Level Gauges and these new regulations.
Our Leak Gauges provide simple and reliable interstitial leak detection for AST’s.
Plus, in regards to the Fire Protection section of the document, our gauges are offerered with an optional Glass Lined Calibration and a Gauge Guard which should bring the gauges up to fire code.  (Ask your local inspector.  Any questions, or explanation on these options please call Lee Geurts at 920-434-8860.)  For a visual on these options, visit our Parts and Accessories page.
Reblogged by Lee Geurts

www.ksentry.com

DEF Storage Tank Regulation

DEF STORAGE TANK REGULATION

Source: PEI Journal | Written by Rick Long

REGULATION OF TANKS CONTAINING DEF

BACKGROUND

Nitrogen oxide (NOx) is a major air pollutant that contributes to smog, asthma and respiratory and heart diseases. It’s a by product of diesel fuel’s high combustion temperatures, which results from the high frictional heat levels created by compressing air in the cylinders to the point at which it can ignite diesel fuel without a spark. This is unlike a gasoline engine, which uses spark ignition to burn gasoline.

Beginning in January 2010, no new on-road vehicles can be sold without meeting EPA’s tougher Tier 2 Emission Standards
for Light Duty and Heavy Duty Vehicles. The new standard is 0.2 grams of nitrogen oxide (NOx) per brake horsepower. This regulation will reduce allowable nitrogen oxide levels by 90 percent from today and by 96 percent from 1994.

While gasoline engines have no problem meeting the new standard, vehicles with diesel engines have to utilize new technology to achieve the more stringent emission regulations.

The technology most vehicle and engine manufacturers will rely on is Selective Catalytic Reduction (SCR), which uses a urea-based diesel exhaust fluid (DEF) and a catalytic converter to change smog-forming nitrogen oxides into harmless nitrogen and water vapor. SCR treats exhaust gas downstream of the engine. Small quantities of DEF are injected into the exhaust upstream of a catalyst, where it vaporizes and decomposes to form ammonia and carbon dioxide. The ammonia (NH3) and SCR catalyst then convert the NOx into nitrogen and water.

COMPOSITION OF DEF

Current DEF formulations are a nontoxic, colorless and nearly odorless mixture of 32.5 percent chemical urea and 67.5 percent deionized water. Urea is the nitrogen-containing compound that transforms into ammonia when heated. Similar urea/water compounds are used in various industries, including extensive application as an agricultural fertilizer.

DEF is not a fuel; it also is neither flammable nor combustible. The product is also extremely heavy—at just over nine pounds per gallon.

STORAGE OF DEF

The industry expects diesel exhaust fluid (DEF) to be stored in small-size containers, drums, totes and intermediate bulk
containers (IBCs), as well as in bulk from both aboveground and belowground tanks.

While the initial supply of DEF will most likely be in packaged containers, larger-scale bulk storage and dispensing is just around the corner. One example suggests why: New truck models will have onboard DEF tanks capable of storing up to 20 (or more) gallons of DEF. A driver with even a mid-sized 13-gallon DEF tank would have to cart and pour almost 120 pounds of packaged DEF for a complete fill-up (13 gallons x 9.2 pounds per gallon = 119.6 pounds).

Given such realities, our industry must understand as quickly and authoritatively as possible how the federal government and
the states plan to regulate larger-scale bulk storage and dispensing of DEF. Good information will be crucial if businesses are to make sound decisions and commitments in the design of their DEF refueling operations.

ABOVEGROUND DRUMS, TOTES, IBCS, AND TANKS

Most people associated with the petroleum marketing and equipment industries know that aboveground tanks (ASTs) storing “oil” are regulated by EPA under the Spill Prevention, Control and Countermeasure (SPCC) rule. Since DEF is composed of aqueous urea which does not meet the SPCC definition of “oil,” ASTs containing DEF (including drums, totes, IBCs and tanks) are not regulated by EPA.

However, a word of caution is necessary here: Some states develop and enforce regulations that are more stringent than the federal rules. Check your state’s aboveground storage tank regulations before installing any AST containing DEF.

OVERVIEW OF FEDERAL UST PROGRAM

The federal underground storage tank (UST) regulations apply only to underground tanks and piping storing either petroleum or certain hazardous substances.

Today, the federal EPA estimates that approximately 617,000 underground storage tanks at close to 233,000 facilities operate under the federal UST program. Nearly all these USTs contain petroleum. Most estimates are that less than 10,000 tanks hold hazardous substances covered by the UST regulations.

Just as DEF does not qualify as an “oil” under EPA’s AST program, aqueous urea is not a “petroleum” substance under EPA’s UST program and therefore is not regulated as a petroleum product.

By itself, aqueous urea also falls outside of EPA’s definition of a “hazardous substance.”

Some confusion in the regulatory community develops, however, because DEF may contain up to 0.2% ammonia, and ammonia is one of about 1,200 substances identied as a hazardous substance under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). That becomes important because UST systems that store substances identied as hazardous under CERCLA are subject to the same requirements as petroleum UST systems, except that hazardous substance tanks must have secondary containment and interstitial monitoring. That means hazardous substance USTs must meet the same requirements as petroleum USTs concerning correct installation, spill, overll and corrosion protection, corrective action, and closure.

DE MINIMIS CONCENTRATION?

But another wrinkle may come into play in determining whether CERCLA will apply to UST systems containing DEF.

The federal rules exempt from federal UST regulations “any tank system that contains a de minimis concentration of regulated substances.” Rather than dening de minimis, the rules permit EPA to determine de minimis levels on a case-by-case basis. In the past, EPA has used the de minimis exception to exempt materials with very small, trace amounts of hazardous substances.

Since the amount of ammonia present in DEF USTs is very small, it is very possible that EPA will determine the level of ammonia would be regarded as de minimis and therefore exempt from federal UST regulations.

The industry has two other things going for it which may lead EPA to exempt DEF. First, the DEF manufacturers and others are very concerned not only with incompatible equipment materials causing the DEF to degrade and/or be contaminated, but also with DEF causing corrosion or somehow reducing the integrity of the equipment that can cause risk to the environment.
That, coupled with the willingness of various groups within the DEF community to insist on secondarily contained underground tank systems with interstitial monitors, might help the decision makers at EPA determine that the environmental risk from DEF USTs will be minimized, even absent EPA regulations.

WHAT HAPPENS NEXT?

The ball is now in EPA’s court. EPA is in the process of developing an official interpretation on whether DEF USTs will qualify for the de minimis exemption. We anticipate an answer soon—most likely this summer—but we don’t have one yet. Once EPA issues its interpretation, PEI will let you know.

Please note: As with ASTs, state UST regulations may be more stringent than EPA’s. Check your state’s UST regulations before installing an UST containing DEF. State UST program contact information is available at EPA’s website www.epa.gov/oust/states/statcon1.htm.

Rick Long is a lawyer and the General Manager of PEI.

Excellent Article by the PEI.

DEF Gauge for AST’s

https://www.ksentry.com/thermaallss.htm

New Vermont Above Ground Storage Tank Installation Regulations and Solutions

Vermont’s Above Ground Storage Tank Rules

What is required for new tank installations?
All new tank installations must have….
http://www.vermontfuel.com/ASTfaqs_files/VTsabovegroundstoragetankregs.pdf
Krueger Sentry Gauge can fill the needs for the a vent alarm or “whistle” that terminates near the fill pipe and the gauging device.
Our most versatile liquid level site gauge is the Type H Therma Gauge
liquid level sight gauge
Add our Remote Audible Whistle Alarm to the gauge and you are good to go.

Green Bay Packers Training Camp- Defensive Line

Of all the free agency losses this year, the one that hurt the most was Cullen Jenkins.  With no proven back up, replacing him on the line is a shot in the dark.  Packers fans have become accustomed to not panicking during free agency.  Every year guys leave and the Packers stick to there guns and there plans, young guys step up, and by the end of the year we don’t even remember the free agency panic we all went through.  This one could be different.

With no proven pass rusher at OLB opposite of Clay Matthews, Cullen Jenkins pass rush ability was what kept defenses honest and helped prevent double teams on Clay (or at least limit double teams).  Here is a depth chart of the D-Line.

  • Left Defensive End: Mike Neal, CJ Wilson, Lawrence Guy
  • Nose Tackle: Ryan Pickett, Howard Green
  • Right Defensive End: BJ Raji, Jarius Wynn

There are a few others, but for the purposes of this article, I am sticking to the top guys.  They have moved Raji from his natural nose tackle position into Jenkins old position.  This move has pros and cons.  The pros:  Pickett is able to go back to his best position at nose tackle after playing Left End last year.  Also, BJ Raji is likely the best candidate on the team for replacing Jenkins.  The cons:  BJ Raji is an awesome nose tackle.  Moving him scares me, but I look forward to be proven wrong.

I have no fears or concerns about Ryan Pickett and Howard Green in the middle.  These guys are effective run stuffers and anchors in the middle.  In the pass game they collapse the pocket and in the run game they force you to run around them.   I love it when the big guys in the middle drop anchor and suck up blocks.  It is such an under rated portion of the game.

At left end (or strong side) is Mike Neal or CJ Wilson.  Mike Neal is a little small for the spot, but he is the strongest player on the whole team which should balance out.  And when he has been in the line up he has shown flashes of brilliance.  Problem is, he has had bad luck with injuries.  I never label a player injury prone.  In most cases it is simple bad luck.  We cannot ignore, however, that he is a young player that needs reps and he currently is not getting them.

The Green Bay Packers are thin on the D-Line.  Hopefully the injury bug stays away and the young guys step up, but even if there are problems history says that the Packers don’t often use 3 down lineman anyway.  Have to find some way to get all of our awesome corners and safeties on the field.

Lee Speakin

www.ksentry.com

Barrel Gauge – Now Available in All Stainless Steel Construction

The Liquid Level Barrel Gauge is now available in

All Stainless Steel Construction.

The Type B-Barrel Gauge can be purchased with all stainless steel wetted components. This includes the bushing, the wetted rods, and the floats.

In order to increase the level gauge’s compatibility with more aggressive liquids (including Caustics, DEF, E85, and more…) this gauge also comes standard with viton gaskets.  The internal piece of the calibration is made of glass.  This alternative gives the plastic calibration added resistance to internal fumes and all types of heat.

All Stainless Barrel Gauge Cut Sheet

To See a selection of all the Barrel Gauges we offer

Barrel Gauge with Galvanized Rods, Plastic Float, and Aluminum Bushing

Barrel Gauge with Stainless Rods, Plastic Float, and Aluminum Bushing

Barrel Gauge with Stainless Rods, Stainless Float, and Aluminum Bushing

Barrel Gauge with Plastic Rods, Plastic Float, and Plastic Bushing

    -Lee Geurts

    Amy is having a baby!!!

    Amy is having a Baby.

    She just graduated from college majoring in Accounting.  She just got married.  She is taking one last class to complete her double major in Business Administration.  She is working full time, and she is studying for her CPA.  I may have missed something, it is hard to keep track.

    Barring any unforeseen surprises, Amy is expecting a Baby Girl.

    Due Date: 01-20-2010

    PS: I got to feel the baby move today

    We have also hired 3 new shop employees.  Mick, John, and Cody.   We will have up some new photos soon to show the new gauge crew.

    -Lee Geurts

    www.ksentry.com

    Overfill Gauge Alarms – New Options Available.

    New models available for the Krueger Audible Overfill Prevention Alarms

    The Audible Alarm accessory for the Krueger Gauge line of products has become a hot selling item.  Able to provide audible overfill protection or audible low level warnings, it is a convenient and inexpensive solution.  In response to feedback, we are now offering the Overfill Gauge Alarm in several new configurations.  All of the configurations are available in both our remote mounted versions and direct mounted versions.

    • DAlarm-FL and RAlarm-FL : With this model, the audible fill alarm is replaced with a flashing light.  The flashing light will trigger with the magnetic sensor in the fill gauge and continues to flash until reset.
    • Dalarm-FL-TO & RAlarm-FL-TO : With this model, there is an audible alarm, a flashing light, and a time out feature.  When triggered, the alarm will sound for 20 seconds, then it will silence itself and chirp every few seconds.  The flashing light will go until reset.
    • DAlarm-DC-FL & RAlarm-DC-FL : This gauge alarm replaces the audible alarm with a set of dry contacts and a flashing light.  The light will flash until reset.
    • DAlarm-DC-FL-TO & RAlarm-DC-FL-TO : This version has dry contacts, audible alarm, flashing light, and a time out feature.  The alarm itself will shut off after 20 seconds and begin to chirp until reset.  The flashing light will go until reset as well.

    Lee Geurts