Direct Reading- Liquid Level Monitor- Stainless Rods

Products:

Liquid Level Gauges Overfill Alert Gauges Leak Detection Gauges Gauge Options & Accessories Other Useful Links:

Liquid Level Monitor Description-Type D-SSR

Liquid Level Monitor Type D-SSR Cut Sheet

This model of liquid level monitor (Stainless Level One) replaces the standard galvanized wetted rods with stainless steel wetted rods, increasing the compatibility with different types of liquids. Plus, with a few accessories, the gauge can become an audible alarm or a remote level monitor.

This mechanical liquid level tank monitor is custom made in house to fit your tank.  Our flexible production process allows for custom sizes that range from 6 inches to 144 inches in total length.  We can also customize the tank level monitor to accommodate for double walls and pipe risers.

Liquid Level Monitor Accessories

Audible High or Low Level Gauge Fill Alarm                                           Remote Reading Level Gauge

Audible liquid level alarm for high or low level alert Remote Reading Level Monitor Display (accessory)

At A Glance Direct Reading Gauge Documentation:

Tank Level Monitor installation, maintenance, operation (All Type D Gauges)

Tank Level Monitor ordering and spec sheet (All Type D Gauges)

** All measurements in inches. For added explanation of these tank gauge measurements, see the Liquid Level Monitor Order Help Page.

Type D Tank Monitor Models

  • Standard Level Monitor Construction - Plastic Calibration, HDPE Lock Nut, Duro Nitrile Gasket, Aluminum Bushing, Galvanized Steel Rods, HDPE Floats.
  • D-SSR-SSF Level Monitor - HDPE Float becomes stainless steel, and galvanized rods become stainless steel.
  • PD Level Monitor - This entire gauge is made of plastic.  The bushing is PVC, the rods are PEEK or Kynar, and the Float is HDPE.

 